The miniature NDIR C3H8 sensor SBH detects 0-75% of the propane (C3H8) concentration based on NDIR technology, which is superior to thermal catalysis and heat conduction technology.
It has the advantages of convenient operation, accurate measurement, reliable operation, simultaneous output of voltage and serial port, and dual beam design. To meet the different requirements of industrial field and laboratory measurement, it is widely used in gas detection and analysis in petrochemical, chemical, coal, medical, laboratory and other fields.
Features
NDIR technology, with long life and full measurement range
Meet the explosion-proof grade Ex iaⅡC T4 Ga
Internal full range temperature compensation
Diffusion sampling, stable performance
High precision, high resolution 0.01%
Small size and fast response
Antiseptic
Easy to install and reduce maintenance
Compatible with digital and analog voltage signal output
Specifications
Measurement range 0-2%vol, 0-75%vol
Measurement method NDIR
Signal output UART_TTL; Analogue output: 0.4V-2VDC
Warmup time: 30s
Response time T90 <15s
Working voltage 3.5-5.5v
Working current 75-80mA
Ex-proof Level ExiaⅡCT4
Ex-proof No. GYB14.1127
Digital signal format RS 232data bit: 8; stop bit: 1; check bit: null
Baudrate 9600 bps
Working temperature -40℃ to 85℃
Dimensions ¢20*19mm (except pin)
Output pin 5pins
Lifespan 8-10years