Outdoor particulate sensor PM3006S is a linear light source-based particle sensor module with laser scattering technology. It is designed to measure the quantity per unit volume of different particle size and can output particle mass concentration PM1.0, PM2.5, PM10 and TSP in μg/m³ at the same time via mathematical algorithm and scientific calibration. Built-in Cubic auto particle identification technology for accurate measurement in different dust source for ambient air quality.
Features
• 4 channels concentration output PM1.0, PM2.5, PM10 and TSP in μg/m³
• High power industrial grade linear laser, accurate identification
• Vehicle-grade constant current sampling structure fan, ensure constant stable sampling flow
• Cubic API technology for intelligent dust source identification
• Wide working temperature -30℃~70℃, suitable for outdoor working environment
• With voltage regulator design and EMC compatibility, strong antistatic ability.
Operating principle - Laser scattering
Measurement range - 0~30,000μg/m³
Output channels - PM2.5, PM10 and TSP
Accuracy - PM1.0/PM2.5:<50ug/m³: ±5μg/m³;50~1000μg/m³: ±10%
PM10: ≤100μg/m³: ±15μg/m³, 100~1000μg/m³: ±15%Reading
TSP (Note 1): ≤100μg/m³: ±20μg/m³, 100~1000μg/m³: ±20%Reading
Condition: -30℃~70℃, 50±10%RH, calibration instrument: Grimm
Data refresh time - 1 second
Time to first reading - ≤ 8 Second
Working condition - -30°C ~ 70°C,0-95%RH (non-condensing)
Storage condition - -40°C ~ 85°C, 0-95%RH (non-condensing)
Power supply - DC 5V±0.1V, ripple wave < 50mV
Working current - < 250mA
Standby current - 5 years (continuous working)