Nitrogen oxide analyzer Gasboard-9805
nitrogen dioxideparticleCO2/02

Nitrogen oxide analyzer - Gasboard-9805 - Cubic Sensor and Instrument Co.,Ltd - nitrogen dioxide / particle / CO2/02
Nitrogen oxide analyzer - Gasboard-9805 - Cubic Sensor and Instrument Co.,Ltd - nitrogen dioxide / particle / CO2/02
Add to favorites
Compare this product

Characteristics

Measured entity
CO, CO2/02, nitrogen oxide, nitrogen dioxide, particle, total hydrocarbon
Application domain
PEMS
Measured value
concentration, temperature, pressure, flow, emissions
Configuration
portable, modular
Technology
NDIR, UV-DOAS, pressure
Other characteristics
battery-powered, with GPS

Description

Introduction Gasboard-9805 is a portable emission measurement system measures CO, CO2 by infrared NDIR technology, NO & NO2 by ultraviolet UV-DOAS technology, and particulate matter, emission flow, GPS data, ambient temperature and humidity, pressure measurement, as well as total emissions automatic calculation. It is a modular design with a built-in battery(more than 4 hours battery lifetime), widely used in on-load real driving emission testing applications. Features • Self-developed gas analysis technologies including Infrared NDIR, UV-DOAS and so on. • Modular design, flexible to use. • Excellent performance meets high measurement standards. • Easy operation, supports testing process guidance, data storage, and report generation functions. • More than 4 hours endurance of the built-in battery, no external battery needed supports complete real driving emission pollutant test. • Great environmental adaptability, not affected by vehicle vibration, heavy pressure, ambient temperature, and humidity change. Specifications Gases Measurement: Range: CO:0~5000-50000ppm ; CO2:0~20% ; NO:0~3000ppm; NO2:0~1000ppm Resolution: CO2: 0.01%; CO.NO,NO2: 1ppm Precision: ≤1%F.S. Accuracy: <±2% of reading or ±0.3% F.S., whichever is greater Sensor Response Time T10-90: <2.5s System Response Time T0-90: ≤10s Zero Drift (4 hours): CO:≤±50ppm; CO2:≤±0.10%;NO, NO2:≤5ppm Span Drift (4 hours): CO: ≤2% of reading or ≤±50ppm, whichever is greater; CO2: ≤2% of reading or ±0.1%, whichever is greater; NO, NO2: ≤2% reading or ≤5ppm, whichever is greater Working Environment Temperature: (5~40) ℃
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.