PM2008 laser particle sensor module is based on laser scattering technology, designed with all metal shielding, ultra-thin (12mm) which is used to detect particle concentration size between 0.3μ-10μm exactly in the air and real-time output PM1.0、PM2.5、PM10 in μg/m3 directly via mathematical algorithm and scientific calibration.
Features
▪ Real-time output PM1.0、PM2.5、PM10 in μg/m3 available
▪ All metal shielding, strong anti-interference
▪ Smaller and thinner structure design, height only 12mm
▪ High accuracy, high sensitive and quick response (≤8s)
▪ Signal output optional: UART, I²C
Specifications
Measured particle size - 0.3μm~10μm
Measurement range - 0~5000μg/m³
Measurement accuracy for PM1.0&PM2.5 - 0 ~35μg/m³, ±5μg/m³ 35μg/m³~500μg/m³, ±15% of reading
Measurement accuracy for PM10 - 0~100μg/m³, ±30μg/m³ 101 ~500μg/m³, ±30% of reading
Condition - 25±2℃,50±10%RH
Reference instrument - GRIMM
Dust Source - Cigarette +Arizona A1
Time to first reading - ≤8s
Response time - 1s
Working temperature - -10℃~60℃
Working humidity - 0~95%RH(non-condensing)
Power supply - DC5V±0.1V
Ripple wave - <50mV
Working current - <100mA(working); <200μA(standby)
Signal output - UART_TTL, I²C, PWM(customized)
Dimensions - W47.8*H36.8*D12(mm)