The DO output module offers a total of 16 purely digital outputs on SAE J1939. This makes it ideal for switching worklights on and off, for example. The temporary total current of the module is 52 A..
Mechanical Data
Dimensions - 97 x 265 x 34 mm
Weight - 680 g
Material (Housing) - PA, reinforced
Power Connector - DT-18 (A-cod.)
IO connector - DT-4
Electrical Data
Operating Voltage - 8 … 32 V DC
Operating Current per Contact / Potential (max.) - 13 A
Sum Current (max.) - 52 A
Supply Protection - Reverse polarity protection
Block diagnoses - Undervoltage | Overvoltage | Overtemperature
LED Indicators - Power: blue | Bus: green | Status: green | Actuator Power: blue | Signal: yellow | Error: red
Outputs
DO output current max. - 2x 10 A | 14x 4 A
Output Protection - Overload | Short Circuit
Output Diagnoses - Actual Current | Overcurrent | Short Circuit
Environmental Conditions
Ambient temperature - -40 °C…+80 °C
Storage temperature - -40 °C…+85 °C
Standards & Approvals
EMC - EN 61000-6-2 | IEC/EN 61000-6-3 | EN 61000-6-4 | ISO 13766-1 | ISO 13766-2 |
Suitable For: - CCpilot V1200, xtremeDBmini, CCpilot V700, CCpilot V1000
Product Family: - xtremeDB
Port Number: - 8
Connection: - DT-4, DT-18
Baudrate: - 250, 500 kbit/s
Output Signal Type: - DO [4 A], DO [10 A]
Auxiliary Voltage: - 8 … 32 V DC
Housing Material: - Polyamide, reinforced
Operating Temperature: - -40°C ... +80°C
Mounting system: - 2x 6 mm round hole + 1x slotted hole
Standards / Approvals: - ISO 13309, EN ISO 13766-1, EN ISO 13766-2