Input signal conditioning module DSCA34 Series
for RTDisolated2-wire

input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
input signal conditioning module
Add to favorites
Compare this product
 

Characteristics

Signal type
input
Options
for RTD
Other characteristics
isolated, 2-wire, 3-wire, linearized, DIN rail

Description

Each DSCA34 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high-level voltage output. Signal filtering is accomplished with a five-pole filter which provides 85dB of normal-mode rejection at 60Hz and 80dB at 50Hz. An anti-aliasing pole is located on the field side of the isolation barrier, and the other four poles are on the system side. After the initial field-side filtering, the input signal is chopped by a proprietary chopper circuit. Isolation is provided by transformer coupling, again using a proprietary technique to suppress transmission of common mode spikes or surges. RTD excitation is provided from the module using a precision current source. Lead compensation is achieved by matching two current paths which cancels the effects of lead resistance. The excitation current is small ( approx. 0.25mA) which minimizes self-heating of the RTD. Module output is either voltage or current. For current output models a dedicated loop supply is provided at terminal 3 (+OUT) with loop return located at terminal 4 (-OUT). The system-side load may be either floating or grounded. Special input circuits provide protection against accidental connection of powerline voltages up to 240VAC and against transient events as defined by ANSI/ IEEE C37.90.1. Protection circuits are also present on the signal output and power input terminals to guard against transient events and power reversal. Signal and power lines are secured to the module using screw terminals which are in pluggable terminal blocks for ease of system assembly and reconfiguration.

Catalogs

No catalogs are available for this product.

See all of Dataforth Corporation‘s catalogs

Other Dataforth Corporation products

DSCA34-xx Linearized 2- or 3-Wire RTD Input Signal Conditioner

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.