• oilfree B280R80 compressor (5.7 m3/h [at 50 Hz); 6.8 m3/h [at 60 Hz]) 100 bar)
• vacuum compressor 3.3 m3/h (at 50 Hz) and 3.9 m3/h (at 60 Hz), final vacuum 3 mbar
• oilfree suction pump (15 m3/h [at 50 Hz); 18 m3/h (at 60 Hz)), final vacuum 1 mbar)
• particle filter 1 um
• operation and indication of important process parameters via 10" touch screen
• indication units in bar / mbar, kPa or psi / torr to be selected on the touch screen
• fork lift slots
• fixing and steerable rollers
• connecting hoses for all gas mixtures with pressure reducer
• C4-FN: with ball valve DN8 (connection 1.030-14NGO-RH-EXT)
• Oxygen (02): with pressure reducer (connection DIN477 no. 9 - G3/4 )
• Carbon dioxide (COz): with pressure reducer (connection DIN477 Nr. 6 - W21.8
X1/14')
• Nitrogen (Nz): with pressure reducer (connection W24.32x1/14")
• space for placing C4-FN cylinder with cylinder scales
• space for placing N2, 02, COz cylinder
• mixing vessel 100 l/ 16 bar
• digital weighing scales for mixing vessel, accuracy $ 0.02 % i. e. $ 2 g gas proportion
per mixing cycle
• wrenches for DILO couplings and filters
• paint: anthracite-green
The mixing unit has been specially developed for the handling of gas mixtures based on C4-FN and their specific requirements. A total of four gas components can be mixed. The gas mixture is circulated by the compressor to generate a homogenous mixture. Using the integrated compressor, the generated gas mixture can be filled directly into gas compartments up to 20 bar. For this purpose, the mixing unit is equipped with a low pressure outlet DN20 (M48x2).
The gas mixture is filled into cylinders with up to 93 bar via the high-pressure outlet.