Ultra-miniature, in-line voltage output, all welded, piezo-ceramic shear plate sensing element. The low mass of the A/128/V renders it transparent in the vast majority of light weight structure vibration measurement applications. The A/128/V is adhesive mounted. A detachment tool is provided to shear adhesive joints. Shock removal is to be avoided as being deleterious to the integrity of the transducer. Abrasive cleaning of the attachment face will reduce base thickness over time; sparing use of adhesive will aid longevity. Signal outlet is via a 10-32 UNF microdot socket on the QF/28, in-line on the cable assembly.
All DJB Accelerometers are calibrated on site prior to despatch, and are accompanied by a calibration chart with temperature and frequency responses listed. Periodic calibration can be carried out with our VC-01 Handheld Calibrator whilst we also offer a full calibration service including cross axis checks to aid accuracy of data. We are able to provide this service for all makes of accelerometer with a full report given for each device. Please contact us with an enquiry
Cable Repair Service to make current cabling as good as new, cutting costs whilst good for the environment
Specialist Cable Assembly - for all manufacturers