for AC networks, DC, AC/DC, for three-phase systems, for low voltage network, with insulation fault location, for single-phase electrical networks, with automatic reset, with manual reset, with temperature monitoring
Contact configuration
3 NC, 3 NO
Mounting
DIN rail
Communication
RS485, Modbus RTU
Applications
for motors, capacitor, for electric vehicle charging stations, for generators, for pump, for switchgear, for transformers, grid and system

Description

SRI3/I2 INJ - Industrial insulation fault locator controller - injector - 6 Din modules The SRI3/I2 INJ insulation monitor allows you to continuously monitor the status of networks with neutral isolated from earth (IT systems). The instruments are able to detect insulation defects due to the resistive component, even in the presence of parasitic DC voltages. The tools offer two differentiated reporting thresholds (Alarm and Fault). To carry out the fault finding procedure in the IT network, SRI3/I2INJ must be combined with at least one I2FL12 or I2FL18 fault finding expansion. Localization is made possible thanks to special FL series toroids (one for each departure to be controlled). When the insulation resistance of the system falls below the set threshold, the device will start the fault locator function. At the end of the search, on the display of the I2FL12 or I2FL18 expansion, the drawing of which or which outputs are responsible for the decrease in the insulation level will appear. For the fault localization function, a current is applied (settable from setup to 2mA, 4mA or 6mA) in relation to the type of system to be monitored (compliance with IEC61557-9 annex A). control with variable frequency signal injection network to control: AC/DC ≤500 Vcc/Vca – DC ≤700Vcc 2 fault intervention thresholds + alarm Ran adjustment: 5 KΩ ÷ 2 MΩ display Mains voltage display with over/under threshold setting 3 independent NO-C-NC contacts password protection setup

Catalogs

No catalogs are available for this product.

See all of DOSSENA‘s catalogs

Other DOSSENA products

Industrial insulation monitoring device (IMD) with fault location function

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.