The Series FDT Flush Diaphragm Transmitter is designed for highly cyclical conditions. Flush sensor feature prevents any potential inaccuracies due to build-up or blockage which is a typical problem found in most non-flush transmitter sensors.
PRODUCT APPLICATIONS
OEM
Hydraulic systems
Process systems
FEATURES
Performs well in high cyclical environments with the presence of water-hammering or spiking for long service life
Specifications
Service:
Compatible liquids and gases, adhesives, slurries, materials that can harden, or where a pressure cavity is not desired.
Wetted Materials:
316 & 15-5 SST.
Compensated Temperature Limits:
0 to 170°F (-18 to 77°C).
Pressure Limit:
150% FS; Burst: 200% FS.
Thermal Effect:
±1.5% FSO over compensated range.
Power Requirements:
8-38 VDC.
Output Signal:
FDT-A: 4-20 mADC; FDT-V: 0-5 VDC.
Response Time:
<1 mS.
Loop Resistance:
FDT-A: 0-1.5 ohms; FDT-V: ≤100 ohms.
Electrical Connections:
4 pin.
Process Connection:
7/16-20 UNF male flush diaphragm. Optional 1/4" male NPT.