The Series FDT Flush Diaphragm Transmitter is designed for highly cyclical conditions. Flush sensor feature prevents any potential inaccuracies due to build-up or blockage which is a typical problem found in most non-flush transmitter sensors.
PRODUCT APPLICATIONS
OEM
Hydraulic systems
Process systems
FEATURES
Performs well in high cyclical environments with the presence of water-hammering or spiking for long service life
Service:
Compatible liquids and gases, adhesives, slurries, materials that can harden, or where a pressure cavity is not desired.
Wetted Materials: - 316 & 15-5 S ST.
Accuracy: - ±0.5% FS (includes non-linearity, hysteresis: and repeatability).
Stability: - ±0.25% FS per year.
Temperature Limits: - -40 to 200°F (-40 to 93°C).
Compensated Temperature Limits: - Oto 170°F (-18 to 77°C).
Pressure Limit: - 150% FS; Burst: 200% FS.
Thermal Effect: - ±1.5% FSO over compensated range.
Power Requirements: - 8-38 VDC.
Output Signal: - FDT-A: 4-20 mADC; FDT-V: 0-5 VDC.
Response Time:
<1 mS.