Possible applications
Fume cupboard control
Exhaust air control
Simple receiver installation in seconds
The transmitter of the FDS 200 set with DIBt approval monitors the window position and transmits the information by radio to an intermediate plug receiver with a switched 5 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site.
Performance features
TÜV tested with DIBt approval Z-85.2-10
Radio link and battery monitoring
Relay contact fused with 5A
Mains plug fuse
4 spacer plates for magnet (height adjustment window)
Expandable with additional transmitter for second window
Expandable with additional receiver for further exhaust air systems
Simple receiver installation in seconds
Functional description:
By using the FDS 200 radio exhaust air control, an exhaust air system can only be used when the window is open and the necessary supply air can flow into the room. A transmitter on the window sash monitors whether the window is open or closed and transmits this information by radio to the receiver. This is simply plugged in between the socket and the mains plug of the extractor hood and only releases the power supply when the window is tilted or open. The mains plug fuse prevents the appliance plug of the cooker hood from being reconnected. The receiver is simply plugged between the socket and the mains plug of the cooker hood. The mains plug fuse prevents the appliance plug of the cooker hood from being accidentally reconnected.