This comfort package without DIBt approval includes a classic FDS 200 exhaust air control set consisting of a radio window switch with built-in receiver and an FTW exhaust gas temperature monitor with integrated transmitter for long, completely free (unjacketed) stovepipes at a minimum height of 80 cm (measured from the top edge of the stove). This means that for very rarely used furnaces, a window does not always have to be opened as well every time the exhaust air system is used.
Hint: Involve your chimney sweep in your planning before ordering so that nothing stands in the way of acceptance afterwards. There are significant regional differences, on which Elektrotechnik Schabus has no influence.
DESCRIPTION
Performance features
smallest design, high temperature resistant due to special metals and ceramics
approved for use in heat generating plants,TÜV DIN tested, DIN EN 14597_2012-09
intrinsically safe design, maintenance-free with professional mounting on the flue pipe
Changeover contact with radio transmitter 868 MHz for release of the exhaust air system in case of cold combustion site
max. medium temperature 500°C, at guard plate 180°C, at switch / transmitter housing max. 65°C
external short helix antenna for best radio performance
internal lithium battery for up to 6 months operation
Increased safety, release of the exhaust air system only with functioning window solenoid or thermoswitch
the assembly is carried out by a specialist company
Functional description:
By using the FTW 519 radio temperature monitor on the free stovepipe, an exhaust air system can only be used when the stove