Possible execution standards IEC 60034, CSA C22.2 No.100 – 14, UL 1004, according to NEMA MG1
Welded casing, water-cooled stator
IEC size 200 – 500
Performance range up to 2.000 kW
Rotational-speed range in operation with VFD 0 – 3000 r/min
Voltage up to 1.000 V
Standard design: IM B3 (IM1001), IM B35 (IM2001), IM B5 (IM3001), IM V1 (IM3011) special design available on demand
Protection type up to IP67
Insulation class/temperature rise H
Noise level < 80 dB(A)
Additional equipment: all common temperature and vibration sensors, various encoders and radial shaft seals