Increasing use of MAINS SIGNALLING to control or gather data is a new challenge to electronic equipment. This differential mode disturbance of mains power lines is regulated by the standard IEC 61000-4-19 to perform tests in the frequency range 2kHz to 150kHz. Electricity meters are particularly vulnerable, signalling on the current circuit with potential to generate measurement error. An enhancement to the already popular IMU series of EMC testers, IMU SLAVE SMART V1I1 includes CW and MODULATED disturbance source, CDN for VOLTAGE circuits, REFERENCE meter connections and a 25A current source. Direct control from IMU series interfaces includes graphics and pre-programmed tests.
Your Benefits
• Voltage and Current tests possible with one unit
• Exceeds maximum test levels in IEC 61000-4-19
• Integrated Current source up to 25A. Maximum EUT voltage 500Vac
• Controlled directly from IMU3000 or IMU4000 front panel
• All modulation types possible.Connection for Reference meter during Current tests