2x4 digit display
0-1V, 0-10V, 0-4mA, 0-20mA analog order digital input (order option)
Selectable heating/cooling control
Selectable PID, On-Off temperature control
PID control function with accurate self-tuning
Selectable humidification or drying control
Auxiliary output power supply
Time adjustable fan relay output
2 x time adjustable relay control for incubation rotating process
Alarm with buzzer for measured value
CE marked according to European Norms
Environmental Conditions
Ambient/Storage Temperature - 0...50 ºC / -25...70 ºC
Relative Humidity - 80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree - According to EN 60529 Front panel: IP65, Rear panel: IP20
Height - Max. 2000m
Electrical Characteristics
Supply - 230V AC ±10% or 110V AC ±10%, 50/60Hz or 10-30V DC / 8-24V AC ±10% SMPS
Power Consumption - 5.4VA
External Connections - Plug-in terminals
Scale - Temperature: Selectable 0~20 mA / 0~10 V for analog output sensor, -40...125 °C for digital output ENDA sensor
Humidity: Selectable 0~20 mA / 0~10 V for analog output sensor, 0...100 RH% for digital output ENDA sensor
Accuracy - ±%0,5 (of full scale)
Line Resistance - 100kohm (0-1/10 V), 10ohm (0/4-20mA)
Output
15V DC Output - 50mA 15V DC output for auxiliary power supply
Heat Output - Relay: 250V AC, 10A (for resistive load), NO
Humidity Output - Relay: 250V AC, 10A (for resistive load), NO
Fan Output - Relay: 250V AC, 10A ( for resistive load), NO
Rotate(R) and (L) Output - Röle: 250V AC, 10A (rezistif yük için), NO
Life Expectancy - Mechanical 30.000.000 operations (under no load), Electrical 100.000