STACK GAS SAMPLING SYSTEM
The dry extractive SEC™ system dries the gas sample at the sampling point, eliminating the necessity of an expensive heated sampling line.
It uses an exclusive high performance permeation technique, designed to meet almost all gas sample conditions. Ideal for highly soluble and corrosive gases.
Optional built-in temperature & velocity sensors or STACKFLOW 200 flow meter on the same flange
FEATURES & BENEFITS
The SEC sampling system uses the Cold Dry Extractive method (Dry Basis Analysis).
- Sampling probe equipped with double stage particulate filtration
- Direct span gas injection for a complete system calibration
- Permeation-based drying system avoids loss of highly condensible gases (e.g. HCl, SO2,NO2 and HF)
- Automatic & periodic back-purge functionality for longer maintenance intervals
- Clean & dry sample transferred via unheated line (up to 100m distance) at ambient air temperature
- Large selection of probes available (depending on process conditions: stack diameter, gas temperature, water content, particulate concentration)
- Heated probe with choice of materials & lengths
MAIN APPLICATIONS
- Sludge Incineration
- Gas turbines
- Power Plants
- Boilers
- Paper Mills
- Cement
- Boilers
- Paper Mills
- Glass, Petrochemical & Chemical Industry
- Waste Incineration( Municipal Energy from Waste or Industrial)