Interlocking set MGB-L0HE-APA..., without controls or indicators, RC18, on mounting plates
• Interlocking (without guard locking)
• With plug connector RC18
• Mounted on mounting plates
• With escape release
• Unicode
Guard locking type
MGB-L0...
The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position.
Door hinge
A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicator
The LED indicator indicates all important system and status information.
Monitoring outputs
OD
ON when the door is closed
OT
Bolt tongue inserted into the evaluation module
OI
Diagnostics; there is a fault
Escape release
The escape release enables people accidentally shut in to open the guard locked door from the danger zone.