Interlocking module MGB-L0-ARA..., without control or indicator
• Interlocking (without guard locking)
• Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
• With cable entry
• Unicode
Guard locking type
MGB-L0...
The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position.
Door hinge
A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicator
The LED indicator indicates all important system and status information.
Monitoring outputs
OD
ON when the door is closed
OT
Bolt tongue inserted into the evaluation module
OI
Diagnostics; there is a fault