• Locking module (order handle module separately)
• Adjustable door hinge; factory setting: right
• Series connection possible (up to 20 AR devices in series)
• Short circuit monitoring
• 2 safety outputs (semiconductor outputs)
• Up to category 4 / PL e according to EN ISO 13849-1
• Emergency stop
• 2 pushbuttons (illuminated)
• With plug connector M23
• Unicode
• Door position monitoring output
• With escape release (order inner door handle separately)
Door hinge
The door hinge can be changed.
Unicode evaluation
Each handle module is highly coded (unicode). The locking module detects only handle modules that have been taught-in. Additional handle modules can be taught-in. Only the last handle module taught-in is detected.
Guard locking actuated by spring force and power-ON released (closed-circuit current principle).
Lens set
The color of the pushbuttons can be selected using the color cover set included (5 colors).
Escape release
It is used for manual release of the guard locking without tools in an emergency. The inner door handle permits escape from the danger zone.