• Auxiliary release on the front
• With door monitoring contact
• Plug connector BH10
Solenoid operating voltage
AC/DC 24 V +10%, -15%
LED function display
The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.
Guard locking type
TX1
Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
Switching element
ETX B
Slow-action switching contact 2 NC / 1 NO + 1 NC (door monitoring contact)
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).