High-purity hydrogen gas and zero air generator RACK.FID.MB.H2 Series
for gas chromatographymembrane

High-purity hydrogen gas and zero air generator - RACK.FID.MB.H2 Series - F-DGSi - for gas chromatography / membrane
High-purity hydrogen gas and zero air generator - RACK.FID.MB.H2 Series - F-DGSi - for gas chromatography / membrane
Add to favorites
Compare this product
 

Characteristics

Gas characteristics
high-purity
Applications
for gas chromatography
Technology
membrane
Flow rate

Min.: 0.1 l/min
(0.026 us gal/min)

Max.: 5 l/min
(1.321 us gal/min)

Output pressure

11 bar
(159.54 psi)

Description

This unit can provide both hydrogen gas and zero grade air to FID detectors and Carrier gas on Gas Chromatographs. Hydrogen gas is produced from deionised water using the exclusive 100% titanium Proton Exchange Membrane (PEM) technology for H2, which provides a very high purity reliability and new longer life. Zero air is produced by purifying compressed air sourced from the air network to a total hydrocarbon concentration of < 0.05 ppm (measured as methane). The RACK.FID. MB.H2 generator combines the hydrogen serie MB.H2 and Zero air serie ZA generators in one unit. The touch screen LCD interface provides simple and user friendly management of all functions on the unit. Reference : RACK.FID.MB.H2.(H2 flow rate) Improved chromatograph result The reduction of hydrocarbons on zero air part, including,methane to < 0.05 ppm decreases the background noise level and gives the baseline much better stability, considerably increasing detector sensitivity and ensuring precise analytical results. The use of hydrogen as a carrier gas allows lower temperature elution, thus extending the life of the chromatograph column. Hydrogen as a carrier gas is faster and more sensitive than the more-expensive helium. Run time savings of 25% to 35% without a decline in resolution. Increased laboratory efficiency A constant, uninterrupted gas supply of guaranteed purity eliminates interruptions of analyses to change cylinders and reduces the amount of instrument re-calibrations required. Save money The unit only requires connection to a suitable socket and to external source of compressed air for the zero air part. The investment can be paid back in less than one year.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.