KAPPA-M instrument designed to measure and totalize (weight, load, preasure, length, or DC current with external shunt) accepts transmitters like Load-Cell, Preasure transmitters, Potentiometers, Shunts, etc.
Specialy useful to measure Rate and total Flow or in Galvanic industry to control the quantity of Amperes giving a value related to the added matherial applied on metals.
Functions most significant:
• ±9999 display points –9999999 to 99999999 Total
• High acquisition rate 100 samples / seg.
• Setpoints by Net1, Net2, Total or Mathematic value.
• Direct access to setpoints programming.
• 26 Programmable logical functions.
• Arithmetical operations between inputs (+, -, x, /).
• Lineal or square root function on every physical channel..
• Up to 15 linearization points on every input.
• Integration time base on Second, Minutes, Hours or Days.
• Tare function by key or remote.
• Peak and valley detection included math channel 10ms min.
• Function Hold.
• Two bright level of display.
• ModBus RTU protocol.