These systems, specially designed to monitor biogas from landfills, are mainly composed of:
Infrared analyzer for the analysis of CH4, CO2 and CO
Electrochemical analyzer for the analysis of O2 (oxygen) and H2S (sulfur dioxide / hydrogen sulfide)
Flowmeters for the control and regulation of measurement and calibration flows on the analyzers
Condensate monitor
Explosive pellistor gas detector
Solenoid valves for intercepting the biogas in case of leakage
4-20 mA analog outputs and measurement digital alarms
Technical specifications
Measurable gases: CO, CO2, CH4, H2, H2S, O2
Serial interfaces: RS232 and 485 with Modbus RTU or TCP
Alarm contacts for exceeding thresholds or for anomalous conditions both cumulative and as individual information: for all 24 V, 1 A max.
Explosion control
Power supply: 115V – 230V ± 10%, 50/60 Hz, 50 Va max
Cabinets for safe or classified areas with Eex-p protection (x or z)
Cabinet for installations in areas with extreme temperatures: from -40 to 60 °C, suitable for protection against atmospheric agents
Features
Continuous measurement 24 hours a day without the need for interruptions
Operating even in the presence of humid and dusty samples
Six-monthly calibration check
High safety required by the explosiveness of the measured compound