FESTEC’s IEC 60331-12 tester is used in test conditions where the basic flame temperature is at least 830℃ and tests the cable exposed to flame and mechanical shock that needs to maintain the circuit integrity.
• IEC 60331
- Test for electric cables under fir conditions – Circuit integrity
• IEC 60331 Part 12
- Apparatus – Fire with shock at a flame temperature of at least 830˚C
• IEC 60331 Part 31
- Procedures and requirements for fire with shock – Cables of rated voltage up to and including 0.6/1kV
• IEC 60331-1
- Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
• IEC 60331-2
- Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
• IEC 60331-3
Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including
- 0,6/1,0 kV tested in a metal enclosure
- Test Chamber Size : (W) 2,500 x (D) 1,800 x (H) 1,600 mm
- Test Apparatus(Test Ladder) Size : (L) 1,200 x (H) 600 mm
- AC Motor : 4 pole / 3 P / 220VAC / 60 Hz / 1,550 RPM / 9.40 kg-cm
- Heat Source : Ribbon type Propane Gas Burner
- Burner Dimension : (L) 500 x (W) 10 mm / Space of hole : 3.2mm
- Auto Ignition system
- Mass Flow Controller
; Gas : 15 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S
; Air : 180 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S
- Electric Control : Transformer & Slidacs : 3 Phase 3 wire, 100~1,000V