Current protection relay XR-6 series
voltageDIN railSIL

current protection relay
current protection relay
current protection relay
current protection relay
current protection relay
current protection relay
Add to favorites
Compare this product
 

Characteristics

Measured/monitored value
voltage, current
Mounting
DIN rail
Norms
SIL
Other characteristics
multichannel
Tripping current

Max.: 5,000 mA

Min.: 5 mA

Trigger voltage

Max.: 250 V

Min.: 5 V

Description

Various supply voltages Special characteristics 1 and 2 channel relay As part of an overfill protection / leakage protection system Description The contact protection relays are universal measuring transducers, which input signals (resistance values) with "Namur" specification (DIN EN 60947). Namur" specification (DIN EN 60947) into switching signals of floating output contacts. Further product information The contact protection relays operate according to the closed-circuit current principle, i.e. if there is no overflow or leakage signal, an operating current flows via the transmitter. As long as this is the case, the output relay remains energised. It only drops out when either the response level is reached, the line is interrupted or the supply voltage fails. The contact protection relays are used in conjunction with our overfill prevention devices (T200F...) and leakage probes (T200L...), among others. In potentially explosive areas, the contact protection relay serves as an interface between the Ex and non-Ex areas. The intrinsically safe circuit is galvanically separated from the non-intrinsically safe circuit. The contact protection relays themselves (without additional protective measures) must not be operated in hazardous areas. When installed in an Ex-approved enclosure, operation in the Ex-area is possible. The safe isolation has been tested and certified by TÜV. Design approved as part of an overfill protection system (Z-65.11-404) / leakage protection system (Z-65.40-153) Line monitoring (cable break / cable short circuit) in connection with our overfill / leakage probes Safe galvanic isolation between input, mains and contacts Various supply voltages

Catalogs

No catalogs are available for this product.

See all of Fluid.iO Sensor + Control GmbH & Co. KG‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.