OMA-3010 HCL Trace CL2 Analyzer
The OMA-3010 HCl purity and trace Cl analysis system is an industrial solution promoted by FPI especially for thechlor-alkali industry. The system adopts ultraviolet full spectrum analysis technology and chemometric algorithm, uses the OMA-3000 series industrial process analyzer and high corrosion resistant pretreatment system. The OMA-3010 analysis system can analyze the HCl and Cl2 in the process gas in the same time, and adapt to the poor environment such as strong corrosive, dust containing; it can make the following profits to the PVC enterprises with calcium carbide process:
Prevents explosion accidents guarantees safe production
The system can analyze the Cl remained in the HCl main pipe in real time, and transmit the concentration signal to DCS in real time. Once the Cl content is monitored beyond the set value, DCS can close the C H delivery vale, for preventing explosion. In addition, customers can control the ratio of H and Cl by checking the content of remained.