AS-Interface Base Element
TEBB4 Element - Connect up to 4 inputs, 4 outputs and 1 dual channel safety circuit to the bus in one stack.
TEBB8 Element - Connect up to 8 inputs, 8 outputs and 2 dual channel safety circuits to the bus in one stack.
Each node address can handle either 4 inputs and 4 outputs, or 1 dual channel safety circuits; you only get the nodes you need to maximise available bus addresses.
Extended addressing is used for I/O nodes allowing 64 nodes on a bus; double the number possible on a standard bus.
Connections are made by the standard M12 5 pin QD.
Mating cables are available, part no. Cable-_M-TQ1;2,5,10 and 20m lengths.
Most elements are powered directly from the bus meaning only two wires are necessary to run the whole stack; the Aux power supply is required if a solenoid lock is included in the stack.
The element takes one bay to house the AS-i electronics and includes the base connection element.