Maximum working pressure (PS): 250-210
Test pressure (PT): PS x 1,43 / 1,3 / 1,5
Body: made in painted carbon steel
Standard nitrogen valve : ⅝” UNF
Working temperature (TS): from -20°C to +80°C
Standard bladder: can be used with mineral oils and non corrosive fluids
Installation: horizontal / vertical (nitrogen valve upward)
Compression Ratio:
- recommended: P2/P0 = 2.5
- maximum: P2/P0 = 4
Mechanical life: the number of cycles is inversely proportional to the increase of the compression ratio. For pulsation dampener applications, the nitrogen value must be from 60% to 80% of the working pressure also in relation with the type of pump and the working temperature.
Warranty: see dedicated page
Spare parts: see dedicated page
Available:
- Inside and outside epoxy painted as per standard FOX procedure or as project specification
- Internal lining in different materials
- Bladders in HNBR, EPDM, FPM
- Connection with flange SAE 3000 – SAE 6000, ANSI B16.5 or UNI/DIN
- Special connection on request
- LT series for temperature of – 40°C
- S series for separator of fluid