Maximum working pressure (PS):150-210 bar
Test pressure (PT): PSx1,43 / 1,3 / 1,5
Body: in AISI 316 L stainless steel
Diaphragm: NBR, HNBR, EPDM, FPM, HYTREL
Standard nitrogen valve : ⅝” UNF
Installation: horizontal / vertical (nitrogen valve upward)
Compression ratio:
- recommended: P2/P0 = 2.5
- maximum: P2/P0 = 4
Mechanical life: the number of cycles is inversely proportional to the increase of the compression ratio. For pulsation dampener applications, the nitrogen value must be from 60% to 80% of the working pressure also in relation with the type of pump and the working temperature.
Warranty: see dedicated page
Spare parts: see dedicated page
Also available:
- Outside epoxy painted as per standard FOX procedure or as project specification
- Connection with flange SAE 3000 – SAE 6000, ANSI B16.5 or UNI/DIN
- Connection API spec. 6A type 6BX
- Autoclave or Grayloc connection
- Special connection on request
- Integral flange connection
- High pressure execution, 1379 bar (20'000 PSI)
- Maintenance Free (HSTX-SMF)- Exotic material execution