Product Description
Hot air sterilisation tunnels continuously depyrogenate pharmaceutical glass objects (e.g. vials, syringes, etc.) after being washed in a washing machine and prior to being fed into a filling machine. The tunnels consist of the inlet zone, the sterilisation zone and the cooling zone with an appropriate pressure cascade between the zones. The electrical control system is integrated to ensure a compact design.
Various tunnel sizes are available, depending on the throughput (mass of glass). All safety-relevant functions are constantly monitored electronically.
Technical Details
• Self-supporting stainless steel construction
• Recirculation system with sensitive pressure cascade control between the zones
• Sterilisation temperature up to 350°C
• HEPA filter H14
• Integrated PLC control system (Siemens S7-300)
• Technical documentation according to the Machinery Directive
• Qualification documentation
• GMP-/FDA-compliant design
• CE declaration of conformity
Options:
• Sterilisable cooling zone
• Airtight discharge compartment for the isolator connection
• 15“ touch panel (B&R)
• Electronic chart recorder for process data recording