Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE
High-accuracy digitization
24-bit ADC, 100 kHz sample rate per channel
Status, trigger, tare, alarm, command
Signal conditioning
16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm
3-Way galvanic isolation
Channel to channel, channel to power supply, and bank