The Gas Clip Technologies MGC Dock is an all-in-one stand-alone docking station designed for maximum testing efficiency and portability. It tests up to four detectors simultaneously, reducing the testing time and gas usage.
It's easy to use.
With only two buttons, it’s simple to train workers how to use it for regular bump tests, occasional calibrations, or to deactivate detectors.
It's portable!
It can be optionally housed in a rugged case or a wall-mountable metal enclosure. Logs are stored on a USB flash drive which can easily be transferred to a computer for analysis.
Features
Test 4 detectors at one time
Easy 1 button operation
Robust rechargeable internal battery, up to 1500 tests before recharging
Internal gas cylinder regulator and pressure gauge
USB flash memory for bump test and event log storage
Optional detector configuration and firmware updates via GCT Manager Software
Rugged case or Wall Mount Dock case
No computer required to operate
Detector Configuration/Firmware Updates: In order to keep your fleet of gas detectors compliant with specific settings, we allow for the MGC Dock to program each detector during either bump testing or calibration. The programmable fields are as follows: User ID, Calibration Interval, Bump Interval, Self-Test Interval, Low Alarm, High Alarm, Show Sensor Readings, Hide Bump Due LED and Hide Clock. For example, if your company or facility requires each detector on site to have specific alarm set points and a bump test interval, instead of programming each detector individually, the instruments can be group programmed while simultaneously bump testin using our GCT Manager software.