These pressure switches have been specially designed for dedicated applications such as gas mixers and essentially mounted in cabinets.
Tightness: IP20
Sensing element:
» NBR, FKM or EPDM diaphragm
Function : 1 pneumatic cell NO or NF
Options:
» Constructional safety for ATEX areas by cabinet integration
Uses
These pressure switches have been specially designed for dedicated applications such as gas mixers and essentially mounted in cabinets. Its design allows this pressure switch to be used for installations in hazardous area.
Technical data
Plate Stainless steel
Tightness IP 20
Mechanism Zinc steel / brass
Sensing element NBR diaphragm
(as option) FKM or EPDM
Flange Brass
Piloting pressure (filtration : 5 μm max.)
NO, NF: 1.5 to 8 bar
YNF: 0 to 10 bar
Piloting Fluid Air, nitrogen, etc.
Exhaust NO, NF - non collected
YNF - cell without leakage
* Application for rare or dangerous gases
Process connection¼’’ GF (others: on request)
Pneumatic connectionNO, NF, flexible tube, ext. Ø 4 mm
YNF – M5 threading
Ambient T°-10 to 60°C
Piloting fluid T°-10 to 60°C
Mounting
Direct or panel mounting by 2 fixing holes Ø 5.5 mm