All stainless steel inert gas pressure thermometers are suitable for severe environments and corrosive media.
Technology: inert gas pressure
Connection: Direct or with capillary, bottom or back with or without flange
Process connection: Sliding or fixed
Safety glass
Options:
» 1 or 2 electrical switches
» Filled with glycerine or silicon oil
» Special scale
» 316 stainless steel case
» Oxygen cleaning
» Welded or barstock thermowell
Uses
All stainless steel inert gas pressure thermometers are suitable for severe environments and corrosive media.
Working pressure
Continuous 100% FS
Temporary 120% FS for FS ≤ 500°C
Temporary 110% FS for FS > 500°C
Case 304 stainless steel, bezel ring
Protection class IP 55 (according to EN60529)
Window Plain glass 4mm
Dial White aluminium
Black letters and graduations
Pointer Adjustable
Black aluminium
Window gasket Neoprene rubber
Movement 304 stainless steel
Sensing element Bulb with rigid extension
Material 316L stainless steel
Diameter Ø 10 mm
Capillary 2m to 25m maximum
Capillary protection 304L st.st. armor as option
Process connection ½’’GM or ½’’NPTM
Sliding or fixed
Connection location Bottom – back flange
Back – front flange
Filled case Case and stem
Glycerine (+15...+160°C)
Silicon oil (-45...+250°C)
Stem diameter Ø 6 – 6.4 – 8 – 9,6 – 12 mm
Armor material 316L st.st.
Contact(s) 1 or 2 magnetic contacts Refer to datasheetfc-c821-fren