Unlike traditional circuits, the pressure signal on the actuator in Load Sensing is constantly received and used as a pilot reference point for distributors and pump control.
Thus the hydraulic system works efficiently and every work section consumes sufficient energy compared to traditional circuits. Load sensing proportional directional control valves are actuated with electronic motors which can drive spool super fine. GPV proportional directional control valves makes movements of the application is smoother and reliable.
WORKING CONDITIONS
This catalogue shows technical specifications and diagrams measured with mineral oil of 46 mm2/s – 46cSt viscosity at 40°C temperature.
Spool travel, standard ± 7 mm [±0.28 in]
Spool travel, float position Proportional range ± 4.8 mm [±0.19 in]
Float position ± 8 mm [±0.32 in]
Dead band, flow control spools Standard ± 1.5 mm [±0.06 in]
Linear characteristic ± 0.8 mm [±0.03 in]
Max. internal leakage at 100 bar [1450 psi] and 21mm2/s [102 SUS]
A/B ® T without shock valve 20 cm3/min. [1.85 in3/min]
A/B ® T with shock valve 25 cm3/min. [2.15 in3/min]
Oil temperature
(inlet temperature) Recommended temperature 30 ® 60 °C [86 ® 140 °F]
Min. temperature -30 °C[-22 °F]
Max. temperature +90 °C[194 °F]