Digital multimeter METRAHIT 2+
with bar graph displayportable600 V

Digital multimeter - METRAHIT 2+ - GOSSEN METRAWATT GmbH - with bar graph display / portable / 600 V
Digital multimeter - METRAHIT 2+ - GOSSEN METRAWATT GmbH - with bar graph display / portable / 600 V
Digital multimeter - METRAHIT 2+ - GOSSEN METRAWATT GmbH - with bar graph display / portable / 600 V - image - 2
Add to favorites
Compare this product
 

Characteristics

Display
digital, with bar graph display
Form
portable
Max voltage
600 V
Max current
16 A
Safety rating
cat III
Additional features
frequency, with thermometer
Protection level
heavy duty, IP54, EMC
Power supply
AA LR6 batteries
Applications
industrial, service
Other characteristics
TRMS, AC, DC, autorange, low-noise
Max DC voltage

600 V

Max AC voltage

600 V

Max DC current

10 A

Max AC current

10 A

Max resistance measure

40,000 kOhm

Max frequency measure

1,000 Hz

Max DC voltage resolution

0.1 mV

Max AC voltage resolution

0.1 mV

Max DC current resolution

0.01 mA

Max AC current resolution

0.01 mA

Max resistance resolution

0.1 Ohm

DC voltage precision

0.5 %

AC voltage precision

1 %

DC current precision

1 %

AC current precision

1.5 %

Resistance precision

0.7 %

Process temperature

Max.: 400 °C
(752 °F)

Min.: -50 °C
(-58 °F)

Length

195 mm
(7.68 in)

Width

84 mm
(3.31 in)

Height

35 mm
(1.38 in)

Weight

350 g
(12.35 oz)

Description

Universal auto-ranging multimeter for use in all areas of electrical engineering. The METRAHIT 2+ provides users with all the measuring functions of a highly diverse multimeter: convincing technology with all voltage, resistance, current and temperature measuring ranges, and additional measuring functions and automatic functions. CE Conformity Measuring Category CAT III Protection IP 40 DAkkS National Accreditation Body of Germany Russian Federation Conformity Approval Russian Federation Type Approval - Resolution: 6000 digits (3 6/7 place) and analog bar graph - TRMS measuremnts VAC and IAC - Basic accuracy: 0.5% VDC - Patented automatic blocking sockets (ABS) - Voltage: VDC 100μ to 600 V and VAC 100μ to 600 V - Current: IDC 10μ to 10 A (16 A 30 sec.) and IAC 10μ to 10 A (16 A 30 sec.) - Resistance: 100 mOhm to 40 MOhm - Temperature: -200.0 to +400.0° C, type K thermocouple - Frequency measurement: 0.1 Hz to 1 kHz - Continuity and diode testing - Min-Max measured value storage and DATA hold - DAkkS calibration certificate included as standard feature - Measuring category: 600 V CAT III battery powered
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.