Temperature protection relay T119
thermalsafetysingle-phase

Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase
Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase
Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase - image - 2
Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase - image - 3
Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase - image - 4
Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase - image - 5
Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase - image - 6
Temperature protection relay - T119 - Groupe SANERGRID - thermal / safety / single-phase - image - 7
Add to favorites
Compare this product
 

Characteristics

Measured/monitored value
thermal, safety, temperature
Network
three-phase, single-phase, AC/DC
Applications
for feeder, for transformers
Mounting
panel-mount
Other characteristics
programmable, configurable, adjustable, multifunction, electronic, with fault indication
Trigger voltage

Max.: 240 V

Min.: 24 V

Description

The T119 is a unit developed to monitor the temperature of MV moulded resin and dry-type transformers. It can be used to monitor the windings of your electrical transformer. Description The T119 is a unit developed to control the temperature of MV moulded resin and dry-type transformers. The use of PTC temperature sensors makes it particularly simple and economical. The 3 PTC sensor inputs refer to the alarm (ALL1), trip (ALL2) and fan (FAN) thresholds. Each input can be connected to 1 to 9 PTCs in series. Any sensor or unit anomaly is signalled as a fault alarm. Accessories and options The T119 thermal protection relay ensures the safety of dry or resin-coated transformers: Standard distribution transformer Dual voltage transformer Traction transformer Special dry-type transformers We offer several PTC probe references for connecting your transformer to the T119. Use and maintenance The owner of the equipment is responsible for and liable for any failure to comply with good operating practice and for any failure to deal with anomalies and defects in the field.

Catalogs

No catalogs are available for this product.

See all of Groupe SANERGRID‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.