Compact device used in heating system boiler to check minimum water pressure.
Max static pressure - 6 bar
Fixing working pressure Custom calibration - 0.5 bar
Histeresis - > 0,1 bar
Maximum overload pressure - > 10 bar
Ambient temperature - -20°C ÷ 60°C
Water temperature - < 90°
Voltage - 5Vdc/24Vdc
Terminal connection - 6.3 x 0.8 mm
Hydraulic inlet (PLASTIC) - See connection pag. 6-7 catalogue
Protection Class - IP00
Weight - ∼ 19 grammi / grams
Approval
EN60730-1, EN60730-2-6, EN60335-1-2002
All our products conform to the 2002/95/EC European directive (RoHS).
Storage
Avoid the transducer coming into contact with powders
Do not store in locations with humidity condensation
Pressure switch with Hydraulic Connection - John Guest
Feature: - Food contact material
- - High hystérésis (The high hystérésis is a necessary feature for stable opération in automatic systems)
- - Long working life and small dimensions
- - Maie and Female connection
Pressure switch with Hydraulic Connection - Metallic body
Feature:
- - Heavy duty industrial applications
- - High pressure
- - Long working life and small dimensions