Relevant standards requirement
1. Test Object: battery pack andsystem.
2. Refer GB/T4 part 5.5.2 test method, test according to GT/T2423.17 test conditions.
3. The salt solution was made up with sodium chloride (chemically pure and analytically pure) and distilled or deionized water,Its concentration is (5 + 1)% (mass fraction).
4. (35 ± 2) ℃, the measured pH value is between 6.5-7.2.
5. Placed the test objects in the salt spray chamber for cycling test. Each cycling duration for 24h. Spray salt solution to the test object for 8 hours under the temperature of (35± 2) ℃ , remain for 16 hours. Between the forth and the fifth hour in one cycles should be according to test requirement in GB/T 28046.1-2011, test mode with 3.2.
6. Total 6 cycles testing.
7. Salt spray test is not necessary for the test objects being installed in passenger, luggage or cargo compartments.
Technical Parameters:
Product Name: Complex Salt Spray Test Chamber
Max Load: 1000KG for battery pack
Temp. Fluctuation: ±0.5℃
Temp. Deviation: 2℃
Spray Capacity: 1~2mL/80cm2/hr (Collect at least 16 hours, take the average )
Spray Pressure: 1.00±0.01kgf/cm²
ResolutionTemp: 0.01℃, Humidity:0.01%R.H.
Humidity Range: 30%–98%R.H.
Control Mode : Touch screen programmable control PLC, networking; mobile phone APP alarm; with USB interface, with RJ485 interface can be connected to computer control, exclusive network control software. Remote monitoring and data acquisition.
Internal material : Acid and alkali resistant SUS316 material
External material : Cold and heat resistant steel plate with spray coating
Cooling Mode : Air cooling / water cooling
Total Weight : Approx 7 Tons