Relevant standards requirement:
Temperature shock
1. Test Object: Battery storage pack or system.
2. Li-ion battery pack or system placed in (-40±2)℃~(85±2)℃ alternation temperature, the conversion time of two extreme temperatures is less than 30 minutes. Place the test objects into each extreme temperature keep 8h, test 5 cycles.
3. Observe for 2 hours under the room temperature after testing,
Humidity & Temperature Cycling
1. Test Object: Battery storage pack or system.
2. Refer the GB/T2423.4 Test Db, variable refer the Graph 4,the highest temperature is +80℃,5 cycles. Observe for 2h under the room temperature.
Technical Parameters:
Product Name: Rapid temperature change rate(damp-heat) Test Chamber
Internal Dimension: W2000 X D3000 X H2000mm
Temperature Fluctuation: ±0.5℃
Humidity Fluctuation: ±2.0%RH
Temperature Deviation: 2.0℃
Humidity Deviation: A)>75%RH:≤+2,-3%RH,B)<75%RH:≤±5%RH。
Heating Rate: ≧5℃/min (From -40℃ up to +80℃ , Non-linear load 800kg)
Cooling Rate: ≧5℃/min (From -40℃ up to +80℃ , Non-linear load 800kg)
Temperature overshoot: ≤±2℃
Weight: Approx 5 Tons
Power Supply: AC 380V, 50HZ, 127KW
Noise≤70dB(A Level)
External Material: Galvanized sheet with high temperature electrostatic resin coating at both sides.
Internal Material: 1.2 mm thickness SUS# 304 heat and cold resistant stainless steel with seal welding.
- 24-bit high accuracy 7 inch TFT true colors LCD touch screen.