Relative Standard test requirements
1. Test Object: battery pack and system
2. Test Conditions: Altitude 4000m or the equate air pressure condition, atroom temperature.
3. The test objects stay in the test condition as Item 2 for 5 hours.
4. Subject the test object to 1C(no more than 400A) constant current discharge until reaching the cutoff condition.
5. After testing, observe for 2h under the room temperature.
Technical Parameters:
Internal Dimension: W1600 X D2400 X H1300mm, W2000 X D3000 X H2000mm
Equipment weight: Approx 6 tonApprox 9ton
Power Supply: AC 380V,6.0KWAC 380V,8.0KW
Pressure Range: 10.0KPa—101.3KPa (Adjustable)
Pressure Reducing Time: Less than 30 min
Pressure Recovery Time: Less than 30 min
Pressure Maintenance: ≧10 hours
High Tension Terminal: 4 pieces, Max. DC 500A,1000V
Low Tension Terminal: 4 pieces, Max. DC 500A,1000V
Data Cable Interface: 2 groups, DB9 line
Observe Window: W400 X H600 mm
Auto DoorAdopt hydraulic automatic open design
Inner Material: SUS304# stainless steel+45# steel
External Material: SECC steel plate,powder painted
Power Supply: AC 380V
Other Requirement: PLC touch screen control + computer remote control.
Can be charge and discharge in vacuum condition.
Inner chamber has signal wire interface.
Lighting system and video monitor system
Slide rail installed, test object can be carried into and out automatically.