Battery Short Circuit Test Chamber
Relevant standard requirement
Single Storage Cell Safety Test
6.2.4 Short circuit
1. Charge the single storage cellaccording to 6.1.3 standard
2. The cellis to be short-circuited by connecting the positive and negative terminal with a external resistance of less than 5mΩ for 10 min
3. Observe for 1H
Battery module safety test
6.3.4 Short circuit
1. Charge the battery module according to standard 6.1.4
2. The battery module is to be short-circuited by connecting the positive and negative terminal with a external resistance of less than 5mΩfor 10 min
3. Observe for 1H
Technical Parameters:
Model: BE-XL-2000A, BE-XL-3000ABE-XL-5000A
Max. Operating Current (A): 2000A, 3000A, 5000A
Max. Instantaneous Current(A): 3000A4000A6000A
Temp. Range: Ambient Temperature
Inner Resistance: <1mΩ, <5mΩ, <10mΩ, <20mΩ, <50mΩ, <100mΩ (Optional)
Control Mode: PLC Touch Screen + Computer remote control + Remote controller
Overall Dimension: W700xD1050xH1830mm
Explosion proof Chamber Dimension: 800 X 800 X 800mm,1000 X 1000 X 1000mm (Optional)
Voltage Measurement Range: 0~500V
Short Circuit Response Time: ≦20ms
Data Interface: USB, Data card, etc.
Data Acquisition Module: Independent remote acquisition, multi-voltage / temperature / current acquisition channels ensure data accuracy. Acquisition frequency 100HZ
Short Circuit Mode: Pneumatic + vacuum arc extinguishing
Safety Device: Electric leakage, over current protection, smoke alarm device, abnormal sound light alarm.
Testing Fixture: Customize according to actual testing condition
Power Supply: 220V 50HZ