Testing requirements:After the battery is fully charged according to the specified test method, the battery is placed on the wire mesh of the test tool, and the test tooling is shown in Appendix E.2. If the battery slips during the test, the battery sample can be fixed to the wire mesh with a single wire; if this is not the case, the battery cannot be bundled. Heat the battery with flame and stop heating when the following three conditions occur:
a) battery explosion b) The battery is completely burned c) continuous heating for 30min, but the battery is not ignited, not exploding
Installation environment requirements
1.Ambient température: room température - 30 " C
2.Ambient humidity: <20%~ 65±5%R.H
3.Air pressure: 1MPA (about 8kg)
4.No strong vibration around, no direct sunlight or direct exposure to other heat sources
5.The installation base is ground and the floor is neat and fiat.