The cantilever steel load cell is fixed at one end and loaded at the other end. It adopts steel ball force transmission, upper and lower indenter bearing or double ball head structure, and is equipped with good sealing structure. Good automatic centering after stress, easy installation, convenient use and good interchangeability.
Made of alloy steel, sealed by adhesive, plated by nickel, this model is waterproof, anti-corrosion at defend grade IP66.
Accuracy class
C2
Comprehensive error
±0.03% FS
Output sensitivity
2.0±0.003 mV/V
creep
±0.023% FS/30min
Zero output
±1.5% FS
Input impedance
350±5Ω
Output impedance
350±3Ω
insulation resistance
≥5000 MΩ(100VDC)
Influence of zero temperature
±0.029% FS/10℃
Sensitivity temperature effect
±0.017% FS/10℃
Temperature compensation range
-10℃ ~ +40 ℃
Operating temperature range
-30℃ ~ +70 ℃
Excitation voltage
5VDC ~ 12VDC
Safe overload range
150%
Limit overload range
200%