The Hawke 385 plastic breather drain is a cost effective fitting to prevent condensation and drain moisture from hazardous area enclosures. Dual Certified ATEX/IECEx (along with many more) for use in Increased Safety (Exe) and Dust (Ext) protection concepts.
Cost effective nylon construction
Stainless Steel Internal Sinter
Certified Exe/Ext
M20 mounting thread as standard
Supplied with plastic castellated locknut for mounting to thin walled enclosures
Integral Nitrile O-Ring - Maintains IP66
Application - Hazardous Areas Zone 1, Zone 21, Zone 2, Zone 22
Ingress Protection - IP66 to IEC/EN 60529
Material - Manufactured in Polyamide with Nitrile O-Ring
Series - Fittings for Hazardous Areas
ATEX File Number - Baseefa 11ATEX0153X
CSA File Number - 2700364
Certification -
Ingress Protection: IP66
ATEX/IECEx Protection Class: Ex II 2GD Ex eb IIC Gb; Ex tb IIIC Db
Contruction/Test Stds: IEC/EN 60079-0, IEC/EN 60079-7; IEC/EN 60079-31
ATEX Cert #: Baseefa 11ATEX0153X
UKEx Cert #: BAS21UKEX0043X
IECEx Cert #: BAS11.0075X
Additional Certifications: EQM: 20-11-27224/Q20-11-000979/NB0007
Inmetro: IEx 15.0291X
NEC/CEC: CSA C22.2 No. 0-10
NEC/CEC: CSA/ANSI: 60079-0; 60079-1; 60079-7;60079-31
NEC/CEC Protection Class: Class I, Zone 1, AEx e/Ex eb IIC Gb
Zone 21, AEx/Ex tb IIIC Db
cCSAus Listing: 2700364