The FCTS-S system is developed to provide a stable testing platform for fuel cell stack. The system consists of KDLF series fuel cell specific energy regenerative electronic load, gas flow and pressure control module, gas humidity and temperature regulation control module, cooling module, stack single cell voltage detection module and sampling control and protection module, etc. The system test software independently developed by Kewell is used to test the output characteristics of the fuel cell stack under different working conditions. With the online data monitoring and processing of the fuel cell stack test system platform, the polarization curve, power curve and other characteristic curves of the stack under test can be analyzed to find the optimum output conditions of the stack, and the change in the output voltage of each cell in the stack can be monitored. Ideal for stack performance evaluation and the R&D process of fuel cell stack.
Product Advantages
Online adjustable gas inlet pressure, temperature and dew point temperature for cathode and anode.
Reserved anode connection for hydrogen circulation pump.
Cathode and anode gas with wet/dry switching.
Adjustable test step & each protection variable.
Data recording and analysis capacities, automatic report generation and one-click export.
Double safety protection: hardware & software, with customizable alarm values.
Dual operation mode: Manual/Auto, supports long periods unattended work.
Online hydrogen leak alarm and online insulation detection.
Hydrogen safety discharge channel.
Optional Functions
Gas mix function
Quick dew point function
Hydrogen circulation function
Subzero startup performance test solution