Power cable NYCWY
DINinsulatedflame-retardant

power cable
power cable
Add to favorites
Compare this product
 

Characteristics

Type
power
Format
DIN
Protection
insulated, flame-retardant
Configuration
round, stranded
Core material
copper
Applications
distribution, for building cabling
Material of the insulation
PVC-sheathed
Color of the insolation
black
Norms
IEC
Other characteristics
corrugated
Nominal voltage

600 V, 1,000 V

Temperature

Max.: 70 °C
(158 °F)

Min.: -40 °C
(-40 °F)

Cross-section

Max.: 300 mm²
(0.47 in²)

Min.: 10 mm²
(0.02 in²)

Description

Power distribution cable acc. to DIN VDE 0276-603 / HD 603 S1 / IEC 60502 Permissible conductor operating temperature - +70°C Permissible short circuit temperature (short circuit duration max. 5 s) - +160°C Test voltage - 4000 V Highest permissible voltage - Direct current systems: Conductor/conductor 1.8 kV Direct current systems: Conductor/earth 0.9 kV Alternating current systems: Single phase systems both outer conductors insulated 1.4 kV Alternating current systems: Single phase systems one outer conductor earthed 0.7 kV Three phase systems 1.2 kV; with concentric conductor and a cross section of 240 mm² and above 3.6 kV Minimum bending radius - 12x Outer-Ø Bare copper conductor, single wire acc. to DIN VDE 0295 cl.1 / IEC 60228 cl.1 multi wire acc. to DIN VDE 0295 cl.2 / IEC 60228 cl.2 Core insulation: PVC, compound type DIV4 acc. to HD 603 S1 Core identification acc. to DIN VDE 0293-308 Cores stranded in concentric layers Filling compound Concentric conductor (Ceander), inner layer of corrugated copper wires outer layer of copper tape as counter helix Outer sheath: PVC, compound type DMV5 acc. to HD 603 S1 Sheath colour: black the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers Flame retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2 re = round conductor, single wire rm = round conductor, multi wire sm = sectional conductor, multi wire Part no. 11020520, 11020521 in reference to VDE Designation (N)YCWY The conductor is metrically constructed (mm²). The AWG designation is approximate and purely informative.

Exhibitions

Meet this supplier at the following exhibition(s):

SPS 2024
SPS 2024

12-14 Nov 2024 Nüernberg (Germany) Hall 2 - Stand 230 , 231

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.