The supply station ZD 60 is available in a single and double sided configuration.
The double sided station for assembly in double sided cylinder an bundle battery systems guarantees the interruption free gas supply with manual switching.
The single sided station is for assembly in single sided cylinder and bundle battery systems and ensures a safe cut-off of the gas supply.
With the supply station ZD 60 a maximum pressure of 300 bar can be reduced to a maximum pressure of 10, 20 or 30 bar and held constant. The supply station consists of a single stage central pressure regulator to DIN EN 961 (ISO 7291) with BAM Oxygen certification. The integrated relief valve protects the valve from excessive outlet pressure. Double shut-off valve (double sided station) or a main shut-off valve (single sided station), both certified with BAM, are also feature of the station.
The assembly is mounted on a wall bracket.