1. Products
  2. High-temperature heat flux sensor
  3. Hukseflux Thermal Sensors B.V.

High-temperature heat flux sensor SBG04
robustcalibrationfor cone calorimeter

High-temperature heat flux sensor - SBG04 - Hukseflux Thermal Sensors B.V. - robust / calibration / for cone calorimeter
High-temperature heat flux sensor - SBG04 - Hukseflux Thermal Sensors B.V. - robust / calibration / for cone calorimeter
High-temperature heat flux sensor - SBG04 - Hukseflux Thermal Sensors B.V. - robust / calibration / for cone calorimeter - image - 2
High-temperature heat flux sensor - SBG04 - Hukseflux Thermal Sensors B.V. - robust / calibration / for cone calorimeter - image - 3
High-temperature heat flux sensor - SBG04 - Hukseflux Thermal Sensors B.V. - robust / calibration / for cone calorimeter - image - 4
High-temperature heat flux sensor - SBG04 - Hukseflux Thermal Sensors B.V. - robust / calibration / for cone calorimeter - image - 5
Add to favorites
Compare this product
 

Characteristics

Options
high-temperature, robust, calibration, for cone calorimeter, water-cooled

Description

SBG04 is a water-cooled sensor that measures heat flux. SBG04 is mainly used as a calibration reference standard for testing with cone calorimeters. All specifications and dimensions are standardised for use in cone calorimeters according to ISO 5660 and ASTM E1354 reaction-to-fire tests. The design includes two water cooling tubes fixed at a 90° angle to the sensor body, with a sensor body of a 0.5 inch diameter. The sensor may also be used in flammability, fire resistance, and smoke chamber testing. For other water-cooled heat flux sensors, see the SBG01 and GG01 sensors. SBG04 specifications: Measurand: Irradiance in W/m² (in SI units) heat flux Sensor technology: both Gardon and Schmidt-Boelter Standardisation: all specifications and dimensions standardised for use in cone calorimeters according to ISO 5660 and ASTM E1354 Rated measurement range: 100 x 10³ W/m² Limiting measurement range: 150 x 10³ W/m² Response time (63 %): 12 x 10⁻³ V at rated measurement range Spectral range: 0 to 50 x 10⁻⁶ m Full field of view angle: 180° Black coating emissivity: > 0.95 Calibration traceability: to ITS-90 Rated cooling water temperature range: 10 to 30 °C Rated cooling water flow: > 10 l/h (0.003 l/s), preferably 30 l/h (0.01 l/s) Calibration laboratory management system certification: ISO 9001 Accreditation: not accredited Calibration method: SBGC secondary calibration method according to ISO 14934-3 Standard cable length: 2 m Order code standard version: SBG04-100-02

Catalogs

SBG04
SBG04
5 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.