Solenoid operated, 3-way, direct-acting, screw-in hydraulic cartridge valve.
Operation
When de-energized, SV07-234 allows the fluid to flow from ② to ① , while blocking flow at ③.
When energized, the cartridge spool shifts to connect the flow from ③ to ②, while blocking flow at ①.
While port ① may be fully pressurized, it is not intended to be used as the inlet. If port ① has to be inlet, the flow through ① to ② must be not more than 5.7 lpm (See performance range chart).
Features
Unitized molded coil design, continuous-duty rated coil, cartridges are voltage interchangeable, optional for 24VDC, 12VDC, 110VAC coil voltage.
Coil insulation grade: H, coil protection grade: IP65.
Hardened seat for long life and low leakage.
Efficient wet-armature construction.
Industry common cavity.
Coil duty rating: Continuous from 85% to 115% of nominal voltage
Coil models: SCO113-DC12, SCO113-DC24, SCO113-RAC110
Minimum pull-in voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See other notes
Fluid: Mineral based or synthetics with lubricating properties at viscosities of 7.4~420 cSt (50-2000 ssu)
Installation: No restriction
Cavity: V07-3
Cavity tool: T/H07-3RC-T-G (Rough), T/H07-3FM-T-G (Finishing)